{"id":5091,"date":"2026-08-21T13:08:20","date_gmt":"2026-08-21T16:08:20","guid":{"rendered":"https:\/\/sites.usp.br\/dosimetry\/?p=5091"},"modified":"2026-08-24T13:10:35","modified_gmt":"2026-08-24T16:10:35","slug":"thermoluminescence-characteristics-and-kinetic-analysis-of-brazilian-blue-quartz","status":"publish","type":"post","link":"https:\/\/sites.usp.br\/dosimetry\/thermoluminescence-characteristics-and-kinetic-analysis-of-brazilian-blue-quartz\/","title":{"rendered":"Thermoluminescence characteristics and kinetic analysis of Brazilian blue quartz"},"content":{"rendered":"<p><a href=\"https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0022231326003790?dgcid=coauthor\">Click here to access the full paper.<\/a><\/p>\n<h2 class=\"section-title u-h4 u-margin-l-top u-margin-xs-bottom\">Abstract<\/h2>\n<div id=\"abssec0010\">\n<div id=\"abspara0010\" class=\"u-margin-s-bottom\">This study investigates the thermoluminescence characteristics and kinetic analysis of natural blue quartz from Minas Gerais, Brazil. Structural and elemental characterizations of the sample were performed using X-ray diffraction and X-ray fluorescence. The glow curve, recorded at 1\u202f\u00b0C\u202fs<sup>\u22121<\/sup>, has two well-defined glow peaks at 72\u202f\u00b0C (peak I) and 184\u202f\u00b0C (peak III), with peak I being the most intense. Experiments suggest the presence of at least three additional but less-distinct components near 120, 270, and 330\u202f\u00b0C. The dose-response of peak I over the range 1\u201362\u202fGy is sublinear whereas that of peak III over the same dose range is superlinear. Kinetic analysis, conducted using multiple techniques, consistently suggest that peaks I and III are subject to first-order kinetics. Peak I has an activation energy of \u223c0.9\u202feV and a frequency factor of \u223c10<sup>12<\/sup> s<sup>\u22121<\/sup> whereas for peak III the corresponding values are \u223c0.9\u202feV and \u223c10<sup>9<\/sup> s<sup>\u22121<\/sup>. Based on these kinetic parameters, the estimated lifetimes at ambient temperature are 2\u202f\u00d7\u202f10<sup>3<\/sup>\u202fs for peak I and 2\u202f\u00d7\u202f10<sup>6<\/sup>\u202fs for peak III.<\/div>\n<\/div>\n<div>\n<h3 class=\"section-title u-h4 u-margin-l-top u-margin-xs-bottom\">Keywords<\/h3>\n<div id=\"kwrd0010\" class=\"keyword\">Thermoluminescence; Blue quartz; Dose response; Kinetic analysis; Fading<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Click here to access the full paper. Abstract This study investigates the thermoluminescence characteristics and kinetic analysis of natural blue quartz from Minas Gerais, Brazil. Structural and elemental characterizations of the sample were performed using X-ray diffraction and X-ray fluorescence. The glow curve, recorded at 1\u202f\u00b0C\u202fs\u22121, has two well-defined glow peaks at 72\u202f\u00b0C (peak I) [&hellip;]<\/p>\n","protected":false},"author":25046,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":"","_links_to":"","_links_to_target":""},"categories":[37],"tags":[],"class_list":["post-5091","post","type-post","status-publish","format-standard","hentry","category-publication","entry"],"_links":{"self":[{"href":"https:\/\/sites.usp.br\/dosimetry\/wp-json\/wp\/v2\/posts\/5091","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sites.usp.br\/dosimetry\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sites.usp.br\/dosimetry\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sites.usp.br\/dosimetry\/wp-json\/wp\/v2\/users\/25046"}],"replies":[{"embeddable":true,"href":"https:\/\/sites.usp.br\/dosimetry\/wp-json\/wp\/v2\/comments?post=5091"}],"version-history":[{"count":1,"href":"https:\/\/sites.usp.br\/dosimetry\/wp-json\/wp\/v2\/posts\/5091\/revisions"}],"predecessor-version":[{"id":5092,"href":"https:\/\/sites.usp.br\/dosimetry\/wp-json\/wp\/v2\/posts\/5091\/revisions\/5092"}],"wp:attachment":[{"href":"https:\/\/sites.usp.br\/dosimetry\/wp-json\/wp\/v2\/media?parent=5091"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sites.usp.br\/dosimetry\/wp-json\/wp\/v2\/categories?post=5091"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sites.usp.br\/dosimetry\/wp-json\/wp\/v2\/tags?post=5091"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}